Companies

Check your energy obligations

Enter your consumption for each energy source. We work out the total in tep (tonnes of oil equivalent, toe) and TJ and show which obligations apply to you under Legea 121/2014 (Romania’s energy efficiency law), art. 9.

Your company’s consumption

Legal regime

Which obligations apply depends on the total annual energy consumption recorded.

Do you have an energy management system certified to SR EN ISO 50001:2018?
How do you want to enter consumption?
Enter last year’s total consumption.
MWh/year
MWh/year
+ Add fuels (diesel, petrol, LPG, coke)
tonnes/year

Do you use other energy sources too? Send us an email with your yearly consumption over the last 3 years and its unit of measure.

Result

Legea 121/2014
0tep/year
0.0TJ/year

Enter your consumption to see which obligations apply

Enter your consumption to see which obligations apply

Factors: 1 MWh = 0.086 tep; 1 tep = 41.868 GJ; diesel approximately 1.01 tep/t (0.845 kg/l); petrol 1.051 tep/t (0.745 kg/l); LPG 1.099 tep/t (0.51 kg/l); coke 0.676 tep/t (Legea 121/2014, annex 2; the densities are indicative). We do the final check on the documents you make available to us.

Request a quote

0 tep/year · 1 obligation

See the result ↓

Could you pay less?

Companies active under an eligible cod CAEN (activity code in Romania’s version of the NACE classification) can apply for an exemption of 85% (annex 3a) or 75% (annex 3b) from paying the cost of the certificate verzi (green certificates) for the mandatory quota, if they meet the conditions of OUG 20/2025 (the government emergency ordinance behind the green certificate exemption scheme).

Check eligibility

What you have to do, step by step

Legal guide
In short

If the company you represent uses more than 1,000 tep a year, Legea 121/2014 (art. 9) requires: a manager energetic (certified energy manager), the declarația de consum (annual energy consumption declaration) with the chestionar de analiză energetică (energy analysis questionnaire) by 30 June, the program de îmbunătățire a eficienței energetice (PIEE, energy efficiency improvement programme) by 30 September, and an energy audit. The audit is due every 4 years; an energy management system certified to SR EN ISO 50001 exempts from it only operators that are not SMEs, and only if the certification was based on an energy audit carried out under the law.

The energy audit is carried out by a company authorised by Ministerul Energiei. Energy Management & Audit is authorised as a corporate energy auditor, class II, complex (no. 0079/23.07.2025). See the authorisation

  1. 01Work out your annual consumption in tep

    Add up the electricity, gas and fuels used in a year. Our calculator converts them to tep.

  2. 02Appoint a manager energetic

    Above 1,000 tep a year, the law requires a manager energetic certified by Ministerul Energiei (Ministry of Energy), or an energy management contract.

  3. 03Meet the yearly deadlines and the audit

    File the declarația de consum by 30 June and the PIEE by 30 September, on the EfEnClima platform. Plan the energy audit every 4 years.

The obligations over 4 years

Year 1Energy audit, declarația de consum (30 June) and PIEE (30 September)
Year 2Declarația de consum (30 June) and PIEE (30 September)
Year 3Declarația de consum (30 June) and PIEE (30 September)
Year 4Declarația de consum, PIEE and preparing the next audit
An illustration. Every year: 30 June, the declarația de consum (and the questionnaire, above 1,000 tep); 30 September, the PIEE. Every 4 years: the energy audit.

Thresholds and obligations

Legea 121/2014, art. 9 · in force
Annual consumptionObligationFrequency / deadlineLegal basis
Above 1,000 tep/yearEnergy audit of the entire consumption perimeterEvery 4 yearsLegea 121/2014, art. 9 alin. (1) lit. a)
Above 1,000 tep/yearA manager energetic or an energy management contractYearly: the declaration and the questionnaire by 30 June; the PIEE by 30 SeptemberLegea 121/2014, art. 9 alin. (1) lit. c)
Above 1,000 tep/yearPIEEYearly, by 30 SeptemberLegea 121/2014, art. 9 alin. (1) lit. b), (3)
Above 1,000 tep/yearThe declarația de consum and the chestionar de analiză energeticăYearly, by 30 June, on the EfEnClima platformLegea 121/2014, art. 9 alin. (4)
Below 1,000 tep/yearThe declarația de consumYearly, by 30 JuneLegea 121/2014, art. 9 alin. (7)
Below 1,000 tep/year, operators that are not SMEsEnergy auditEvery 4 yearsLegea 121/2014, art. 9 alin. (5)

All the obligations above follow art. 9 of Legea 121/2014. Audit exemption: an energy management system certified to SR EN ISO 50001 (or an ISO 14001 environmental management system) exempts from the 4-yearly audit, with proof that the certification was based on an energy audit carried out under the law (art. 9 alin. (19)). Sub-units above 1,000 tep at different locations, with no functional link between them, are each treated as a separate unit (art. 9 alin. (2)).

Penalties (art. 18)

  • Energy audit not carried out, above 1,000 tep/year: a fine of RON 10,000 to 200,000.
  • PIEE: RON 15,000–30,000 for not drawing it up, RON 5,000–15,000 for not submitting it.
  • No manager energetic and no energy management contract: RON 10,000–20,000.
  • Declarația de consum not submitted: RON 1,000–5,000 above 1,000 tep/year, RON 2,000–5,000 below that threshold.

Below you will find the future obligations under the directive.

What changes after transposition

Directive (EU) 2023/1791 · not transposed
Status

Being transposed: a draft emergency ordinance published by Ministerul Energiei, not adopted at the date of this update. Until it is adopted, only Legea 121/2014 applies, as set out above.

New criterion

3-year average, all forms of energy, in TJ

Only total annual energy consumption counts, not company size.
Above 85 TJ/year (approximately 2,030 tep)

Certified energy management system

ISO 50001, as SR EN ISO 50001:2018.
Above 10 TJ/year (approximately 239 tep)

Energy audit at least every 4 years

For companies without a certified energy management system.

Future obligations under the directive

  1. Enterprises with a 3-year annual average above 85 TJ (approximately 2,030 tep), whatever their size: an energy management system (EnMS) certified by an independent body, by 11 October 2027 (art. 11 alin. (1)). Romania’s draft emergency ordinance of 11 June 2026 lowers the threshold to 1,000 tep, with the same deadline, and adds a manager energetic and an audit every 4 years.
  2. Enterprises above 10 TJ (approximately 239 tep) without an EnMS: a first energy audit by 11 October 2026, then at least once every 4 years; an action plan based on the recommendations, published with its implementation rate in the annual report (art. 11 alin. (2)). The Romanian draft lowers the threshold to 200 tep.
  3. Above the thresholds, the obligations apply whatever the size of the enterprise; below them, member states set up support programmes (art. 11 alin. (6)).
  4. Consumption above 10 TJ or 85 TJ is made available to the authorities (art. 11 alin. (3)). In the Romanian draft: reporting on the EfEnClima platform by 30 June and a PIEE updated every year by 30 September.
  5. Data centres with at least 500 kW of IT power: yearly reporting and publication of energy performance data (art. 12 alin. (1)); in the Romanian draft, by 31 December.
  6. Public bodies: cut final energy consumption by at least 1.9% a year compared with 2021 (art. 5 alin. (1)); unități administrativ-teritoriale (UAT, local administrative units: communes, towns and cities) below 50,000 inhabitants are exempt until 31 December 2026, and those below 5,000 until 31 December 2029 (art. 5 alin. (3)). Renovate at least 3% of the floor area of public buildings every year (art. 6 alin. (1)).
  7. Local heating and cooling plans: the directive requires them of municipalities above 45,000 inhabitants (art. 25 alin. (6)); in Romania they already apply from 20,000 inhabitants (Legea 121/2014, art. 14^1).
  8. The EU transposition deadline was 11 October 2025 (art. 36 alin. (1)). Romania is late: the European Commission sent a letter of formal notice on 21 November 2025, and the draft emergency ordinance published by Ministerul Energiei on 11 June 2026 had not been adopted by 17 November 2026.
CriterionLegea 121/2014 (in force)After transposition
CriterionAnnual consumption in tep (above 1,000 tep: every operator; below 1,000 tep: the audit is mandatory only for those that are not SMEs)Average consumption over the last 3 years, in TJ
Audit every 4 yearsAbove 1,000 tep/year: every operator; below 1,000 tep/year: operators that are not SMEsAbove 10 TJ/year (approximately 239 tep), without a certified EnMS
Extended obligationsAbove 1,000 tep/yearAbove 85 TJ/year (approximately 2,030 tep): certified EnMS
ISO 50001An energy management system certified to SR EN ISO 50001 exempts from the 4-yearly audit only operators that are not SMEs, and only if the certification was based on an energy audit under Legea 121/2014Mandatory above 85 TJ/year
ReportingDeclarația de consum and chestionar de analiză energetică by 30 June; PIEE by 30 September, on the EfEnClima platformAction plan and annual report
Conversion: 1 tep = 41.868 GJ. The EU deadline was 11 October 2025; the transposition is still a draft (a draft emergency ordinance by Ministerul Energiei, not adopted by 17 November 2026).
Contact

Does this apply to you? We can help with the energy audit.

We carry out the audit energetic complex (comprehensive energy audit) under Legea 121/2014: assessment, technical report and an action plan for consumption and emissions. We also help you implement an energy management system to SR EN ISO 50001:2018, through to certification.

Frequently asked questions

What does 1,000 tep mean, and how do I work out my consumption?

Tep stands for tonnes of oil equivalent, the unit in which the law measures total energy consumption. Add up a year’s electricity, gas and fuels; our calculator converts them for you.

What are the deadlines for the declarația de consum and the PIEE?

The declarația de consum is filed every year by 30 June (above 1,000 tep/year, together with the chestionar de analiză energetică), and the PIEE is submitted every year by 30 September. Both go to Ministerul Energiei through the EfEnClima platform (Legea 121/2014, art. 9 alin. (3), (4) and (7)).

Does a certified ISO 50001 system exempt me from the energy audit?

Only under certain conditions. Under art. 9 alin. (19) of Legea 121/2014, an energy management system certified to SR EN ISO 50001 exempts operators that are not SMEs from the 4-yearly audit, if the certification was based on an energy audit carried out under the law. The other obligations remain.

Can you help me implement ISO 50001?

Yes. We help you implement an energy management system to SR EN ISO 50001:2018: the initial energy review, the policy and objectives, the procedures, staff training and the internal audit, up to the certification body’s audit.